Below "getportcounters" Command can be used to check if there are any Symbol Errors, Link Issues on Switch Ports of IB Switch.
Products to which Article Applies
Infiniband Switches
getportcounters <Switch Port>
For example if you want to check the counters on port 6 above command looks as follows:
getportcounters 6
Below is sample output of above command. If we see SymbolErrors increasing then that indicates there is an issue with the Switch port (loose cable, bad cable, bad switch port or something else)
SymbolErrors.....................0
LinkRecovers.....................0
LinkDowned.......................0
RcvErrors........................0
RcvRemotePhysErrors..............0
RcvSwRelayErrors.................297
XmtDiscards......................6
XmtConstraintErrors..............0
RcvConstraintErrors..............0
LinkIntegrityErrors..............0
ExcBufOverrunErrors..............0
VL15Dropped......................0
XmtData..........................4294967295
RcvData..........................4294967295
XmtPkts..........................717430186
RcvPkts..........................634187063
XmtWait..........................1338332
Products to which Article Applies
Infiniband Switches