Main Menu

Search

Showing posts with label errors. Show all posts
Showing posts with label errors. Show all posts

EXALOGIC: INFINIBAND: "getportcounters" Command To Clear/Reset Errors And Port Counters IB Switch Ports (How To Doc) Connector Ports of IB Switch (How To Doc)

INFINIBAND: "getportcounters" Command To Clear/Reset Errors And Port Counters IB Switch Ports (How To Doc)

getportcounters command can be used to clear/reset errors and port counters on IB Switch ports.

If you want to reset/clear errors and  port counters on 10Gbits/sec ETH connector ports, following commands can be used based on the connector ports which are enabled and being used.

getportcounters 0a-eth -R
getportcounters 1a-eth -R



Below is example snippet of output when we run above command to clear the counters on 0a-eth connector port.
# getportcounters 0A-ETH -R
Reset port counters for connector 0A-ETH-1 Bridge-0 port Bridge-0-2
Reset port counters for connector 0A-ETH-2 Bridge-0 port Bridge-0-2
Reset port counters for connector 0A-ETH-3 Bridge-0 port Bridge-0-1
Reset port counters for connector 0A-ETH-4 Bridge-0 port Bridge-0-1

If you want to reset/clear errors and port counters on specific 40Gbits/sec IB Switch ports below command can be used.
getportcounters <switch connector ports> -R

In above command replace the connector ports with the connector port for which you want to reset/clear errors and port counters. Switch 40Gits/sec connector ports range is from 0A – 15A and 0B – 15B. So if you want to clear/reset errors and counters for 15A, your command will look as follows:
getportcounters 15A -R


Products to which Article Applies

Infiniband Switches

Additional Reference

https://docs.oracle.com/cd/E19671-01/835-0793-03/z40000471973870.html


INFINIBAND: "getportcounters" Command to Check If there are Issues/Problems and Errors On 10Gbits/sec ETH Ethernet Connector Ports of IB Switch (How To Doc)

Below are getportcounters commands which can be run on 0A-ETH and 1A-ETH Ethernet Connector ports of IB Switch to check if there are an RX, TX and CRC errors
# getportcounters 0a-eth | egrep -i "error|CRC"
# getportcounters 1a-eth | egrep -i "error|CRC"

Below is example snippet of above command.
# getportcounters 0a-eth | egrep -i "error|CRC"
RX CRC...........................0
RX errors........................0
TX errors........................0
RX CRC...........................0
RX errors........................0
TX errors........................0
RX CRC...........................0
RX errors........................0
TX errors........................0
RX CRC...........................0
RX errors........................0
TX errors........................0

If we see any gradual or significant increase of RX/TX errors and RX CRC errors over a period of time, then it indicates that there is some issues with 0A/1A ETH connector ports on the IB Switch. It may be lose cabling, bad cable, bad switch port or something else.



Products to which Article Applies

Infiniband Switches.

Additional References

https://docs.oracle.com/cd/E19671-01/835-0793-03/z40000471973870.html


INFINIBAND: How To Validate If any Infiniband (IB) Switch Ports Have Errors/Failures or Issues? ("listlinkup" Command)

Below "listlinkup" command can be used on IB switch to check if any of the Infiniband Switch ports have errors/failures or issues.
listlinkup | egrep -i "error|bad"

If there are any issues on any of the Switch ports you may be AutomaticHighErrorRate or AutomaticBadSpeedOrWidth errors as follows. AutomaticHighError or BadSwitch errors may happen due to lose cabling, bad cable or bad switch port etc.
Connector  0A Present<->  Switch Port 20 down (AutomaticHighErrorRate)
Connector  0A Present<->  Switch Port 8 down (AutomaticBadSpeedOrWidth)


Products to which Article Applies

Infiniband Switches

Additional Reference