Main Menu

Search

Showing posts with label bad. Show all posts
Showing posts with label bad. Show all posts

INFINIBAND: How to check if there is lose cabling or bad cable connection on IB Fabric

One of the ways to identify if there is a bad cable or lose cabling on IB Fabric is to look for SymbolErrors on Ports on IB Switches. If we see SymbolErrors then that would indicate there is a bad cable or lose cabling issue.

Run below command on any of the IB Switches and check if there are any SymbolErrors on any of the Switch ports. If there are no symbol errors then that would indicate that there is no lose cabling or bad cable issue.
ibqueryerrors.pl -rR -s RcvSwRelayErrors,XmtDiscards,XmtWait

Products to which Article Applies
Infiniband Switches

Article Author: Tarun Boyella

INFINIBAND: How To Validate If any Infiniband (IB) Switch Ports Have Errors/Failures or Issues? ("listlinkup" Command)

Below "listlinkup" command can be used on IB switch to check if any of the Infiniband Switch ports have errors/failures or issues.
listlinkup | egrep -i "error|bad"

If there are any issues on any of the Switch ports you may be AutomaticHighErrorRate or AutomaticBadSpeedOrWidth errors as follows. AutomaticHighError or BadSwitch errors may happen due to lose cabling, bad cable or bad switch port etc.
Connector  0A Present<->  Switch Port 20 down (AutomaticHighErrorRate)
Connector  0A Present<->  Switch Port 8 down (AutomaticBadSpeedOrWidth)


Products to which Article Applies

Infiniband Switches

Additional Reference

https://docs.oracle.com/cd/E36265_01/html/E36266/z40001002006287.html